ALCOA+ and Data Integrity: The Foundation of Trustworthy Trial Data

A trial is only as good as its data. If regulators or reviewers cannot trust the data, they cannot trust the results – no matter how positive they look. That is why data integrity is at the heart of GCP, and why it receives so much attention in ICH E6(R3).

The most practical framework for data integrity is ALCOA+.

ALCOA: the original five

  • Attributable – it is clear who recorded or changed the data, and when.
    Example: every entry in a source note is signed or initialled and dated.
  • Legible – the data can be read and understood, now and years later.
    Example: no illegible handwriting or faded thermal printouts without a certified copy.
  • Contemporaneous – recorded at the time the activity happened.
    Example: vital signs written during the visit, not reconstructed from memory a week later.
  • Original – the first record, or a certified copy of it.
    Example: the original ECG tracing, not just a value typed into the CRF.
  • Accurate – correct, complete and reflecting what actually happened.
    Example: corrections made with a single line, reason, initials and date – never with correction fluid.

The "+": four more principles

  • Complete – all data are present, including repeat tests and failed measurements.
  • Consistent – dates, times and sequences make sense across records.
  • Enduring – records are kept on durable media for the full retention period.
  • Available – records can be accessed for review, audit or inspection when needed.

Common data integrity red flags

In audits, these patterns make me look more closely:

  • Identical handwriting and ink across many visits recorded on different days
  • Perfect data with no variability or missing values
  • Source notes created after CRF entry
  • Shared passwords or log-ins for electronic systems
  • Audit trails switched off or never reviewed
  • Lab values in the CRF that differ from the lab report

Most of these have innocent explanations. But each must be explained.

Building a data integrity culture

  • Train staff on ALCOA+ with real examples from their own work.
  • Define source documents for each data point at site initiation.
  • Use individual log-ins for all electronic systems – never shared credentials.
  • Review audit trails periodically, especially for critical data.
  • Encourage honesty: staff should feel safe to report mistakes. Hidden errors are far more damaging than corrected ones.

The bottom line

Data integrity is not a technical issue; it is a culture. Sites and sponsors that live by ALCOA+ produce data that stands up anywhere in the world.

Concerned about data integrity at your sites or vendors? Write to me at anup.cra@gmail.com for an independent review.

– Anup Kumar, Independent Clinical Research Auditor & Consultant, New Delhi